The RKS-01-SOLO radiometer-dosimeter is designed for integrated radiation monitoring of the environment, workplaces, equipment and vehicles, for radiation inspection of scrap metal and recyclables. There is a special automatic mode for vehicle and luggage inspection, accounting for the shielding of the inspected object. The device has a wide range of highly sensitive detection units for alpha, beta, gamma (including the X-ray range) and neutron radiation, which can be integrated depending on the customer’s needs.
The device has a handy LCD readout with an arrow search mode, plus a light and sound alarm.
The device is included in the State Register of the Republic of Kazakhstan under no. KZ.02.01.02637-2024
Manufacturer: SOLO LLP
Country: Republic of Kazakhstan
Warranty period: 12 months
After-sales service: during the entire period of operation
The dosimeter is a wearing device designed to measure:
The dosimeter consists of a control panel and detection units depending on customer requirements. Two detection units can have separate housings or share one housing.
The flattening of nonlinearity of the energy dependence of the sensitivity of scintillators is performed by an analog-to-digital converter. The device performs basic radiation control tasks in accordance with the Hygiene Standards of the Sanitary and Epidemiological Guidelines for Radiation Safety (HS SEGRS) (NRB) and the of the Sanitary Rules of the Sanitary and Epidemiological Guidelines for Radiation Safety (SR SEGRS).
The device consists of a control panel and replaceable detection units.
Characteristic |
Value |
|
Alpha-beta particle detection unit * |
||
Detector |
scintillation type |
|
Active surface area |
40 sq cm |
|
Alpha radiation flux density measuring range |
from 0.05 to 5×105 part/(min×cm2) |
|
Beta-particle flux density measuring range |
from 0.1 to 5×105 part/(min×cm2) |
|
Energy range of detected alpha particles |
from 1 to 10 MeV |
|
Energy range of detected beta particles |
from 0.03 to 5 MeV |
|
Maximum acceptable reference relative error for alpha radiation |
±20% |
|
Maximum acceptable reference relative error for beta radiation |
±15% |
|
Overall dimensions of the detector, max. |
Ø90 mm, length 185 mm |
|
Weight of detector, max. |
0.5 kg |
|
Gamma radiation detection unit |
||
Detector |
scintillation type |
|
Gamma radiation energy range |
from 20 keV to 10 MeV |
|
Measurement range for ambient equivalent dose rate |
from 0.01 to 500 μSv/h |
|
Measurement range for ambient equivalent dose |
from 0.01 to 5×108 μSv |
|
Maximum acceptable reference relative error |
±12% |
|
Overall dimensions of the detector, max. |
Ø40 mm, length 140 mm |
|
Weight of detector, max. |
0.5 kg |
|
Wide-range gamma radiation detection unit |
||
Detector |
scintillation type |
|
Gamma radiation energy range |
from 20 keV to 10 MeV |
|
Measurement range for ambient equivalent dose rate |
from 0.01 to 15×106 μSv/h |
|
Measurement range for ambient equivalent dose |
from 0.01 to 5×108 μSv |
|
Maximum acceptable reference relative error |
±12% |
|
Overall dimensions of the detector, max. |
Ø40 mm, length 140 mm |
|
Weight of detector, max. |
0.5 kg |
|
Gamma, continuous and pulsed X-ray radiation detection unit |
||
Detector |
scintillation type |
|
Gamma radiation energy range |
from 20 keV to 10 MeV |
|
The energy range of the recorded continuous and pulsed X-ray radiation |
from 14 keV to 10 MeV |
|
Range of measurement of ambient dose equivalent rate of gamma radiation |
from 0.01 to 15×106 μSv/h |
|
Range of measurement of ambient equivalent dose of gamma radiation |
from 0.01 to 5×108 μSv |
|
Measurement range for ambient equivalent dose rate of continuous and pulsed X-ray radiation |
from 0.01 to 15×106 μSv/h |
|
Measurement range of ambient equivalent dose of continuous and pulsed X-ray radiation |
from 0.01 to 5×108 μSv |
|
Maximum acceptable reference relative error for gamma radiation |
±12% |
|
Maximum acceptable reference relative error for continuous and pulsed X-ray radiation |
±15% |
|
Overall dimensions of the detector, max. |
Ø40 mm, length 290 mm |
|
Weight of detector, max. |
0.5 kg |
|
Neutron radiation detection unit |
||
Energy range of detected neutron radiation |
from 0.025 eV to 15 MeV |
|
Measurement range for ambient equivalent dose rate |
from 0.1 to 5×105 μSv/h |
|
Measurement range for ambient equivalent dose |
from 0.1 to 1×108 μSv |
|
Maximum acceptable reference relative error |
±20% |
|
Overall dimensions of the detector, max. |
Ø63 mm, length 205 mm |
|
Weight of detector, max. |
0.5 kg |
|
Overall dimensions of the moderator, max. |
Ø300 mm |
|
Moderator weight, max. |
10 kg |
|
Control panel |
||
Overall dimensions of the control panel, max. |
200×120×100 mm |
|
Weight of the control panel, max. |
1.0 kg |
|
Operating temperature range of the control panel and detection units |
from –40°C to +50°C. |
|
For voice guidance and data storage |
from –40°C to +50°C. |
|
LCD data readout display |
from –30°C to +50°C. |
|
Power supply |
built-in 7.2 V lithium-ion battery or included AC adapter with 12 V output voltage |
|
* It is possible to manufacture a detection unit designed to measure only one type of radiation or two separate units, depending on customer requirements |
SPECIALIZED DETECTION UNITS
Characteristic |
Value |
|
Alpha particle detection unit with an active surface area of 70 sq cm |
|
|
Detector |
scintillation type |
|
Active surface area |
70 sq cm |
|
Alpha radiation flux density measuring range |
from 0.05 to 5×105 part/(min×cm2) |
|
Energy range of detected alpha particles |
from 1 to 10 MeV |
|
Maximum acceptable reference relative error for alpha radiation |
±20% |
|
Overall dimensions of the detector, max. |
Ø130 mm, length 150 mm |
|
Weight of detector, max. |
0.6 kg |
|
Alpha particle detection unit with an active surface area of 100 sq cm |
|
|
Detector |
scintillation type |
|
Active surface area |
100 sq cm |
|
Alpha radiation flux density measuring range |
from 0.05 to 5×105 part/(min×cm2) |
|
Energy range of detected alpha particles |
from 1 to 10 MeV |
|
Maximum acceptable reference relative error for alpha radiation |
±20% |
|
Overall dimensions of the detector, max. |
Ø140 mm, length 150 mm |
|
Weight of detector, max. |
0.6 kg |
|
Beta particle detection unit with an active surface area of 70 sq cm |
|
|
Detector |
scintillation type |
|
Active surface area |
70 sq cm |
|
Beta-particle flux density measuring range |
from 0.1 to 5×105 part/(min×cm2) |
|
Energy range of detected beta particles |
from 0.03 to 5 MeV |
|
Maximum acceptable reference relative error for beta radiation |
±15% |
|
Overall dimensions of the detector, max. |
Ø130 mm, length 150 mm |
|
Weight of detector, max. |
0.6 kg |
|
Beta particle detection unit with an active surface area of 100 sq cm |
|
|
Detector |
scintillation type |
|
Active surface area |
100 sq cm |
|
Beta-particle flux density measuring range |
from 0.1 to 5×105 part/(min×cm2) |
|
Energy range of detected beta particles |
from 0.03 to 5 MeV |
|
Maximum acceptable reference relative error for beta radiation |
±15% |
|
Overall dimensions of the detector, max. |
Ø140 mm, length 150 mm |
|
Weight of detector, max. |
0.6 kg |
No. |
Name |
Quantity |
1 |
Dosimeter control panel |
1 |
2 |
Alpha-beta-particle detection unit** |
1** |
3 |
A gamma radiation detection unit/ or a wide-range gamma radiation detection unit/ or a gamma, continuous and pulsed X-ray radiation detection unit** |
1** |
4 |
Neutron radiation detection unit |
1 |
5 |
Moderator |
1 |
6 |
Power adapter |
1 |
7 |
PC connection cable |
1 |
8 |
CD (or flash drive) with software |
1 |
9 |
USB converter |
1 |
10 |
Protective film for alpha-beta detector |
1 |
11 |
Extension cable |
1 |
12 |
Case |
1 |
13 |
How-to documentation (user manual) |
1 |
14 |
Warranty card |
1 |
16 |
Verification certificate |
1 |
* The dosimeter can be supplied with special-purpose detection units described in a separate section ** It is possible to manufacture a detection unit designed to measure only one type of radiation or two separate units, depending on customer requirements |