RU KZ EN
Radioactive aerosol radiometer RAMON-02AD

Radioactive aerosol radiometer RAMON-02AD

Radiometer RAMON-02AD is designed to measure the volumetric activity of long-lived alpha-active aerosols and radionuclides (VA LLA) and dust-radiation factor (DRF) contained in the air of working areas, ventilation emissions, in the air of sanitary and residential areas in uranium mining and processing facilities, at oil and gas facilities, at mining sites, in mines, at polymetallic plants, etc. The radiometer operates in automatic mode.

The device is included in the State Register of the Republic of Kazakhstan under no. KZ.02.01.02637-2024
Manufacturer: SOLO LLP
Country: Republic of Kazakhstan

Warranty period: 12 months
After-sales service: during the entire period of operation

Video with a manual for working with a radiometer: https://youtu.be/TT189OAN_1M 


  • Description

    The radiometer is a portable device for measuring the volumetric activity of long-lived alpha-active aerosols and radionuclides.

    Measurements of the volumetric activity of alpha emitters are carried out by catching aerosols on a filtering analytical tape. The radiometer is designed to operate in automatic mode. There is also a manual control mode.

  • Features
    • Direct measurement of the volumetric activity of long-lived alpha-active aerosols and radionuclides;
    • The device operates 24/7 in automatic mode;
    • It has built-in memory for storing measurements.
  • Characteristics

    MAIN CHARACTERISTICS

    Characteristic

    Value

    Measurement range of volumetric activity of alpha emitters (LLA)

    from 0.01 to 5×105 Bq/m3

    Alpha particle energy range recording

    from 1 to 8 MeV

    Measurement error

    20%

    Filter type

    analytical tape

    Operating mode setting time, max.

    1 min

    Continuous operating time, min.

    24 h

    Power

    from built-in rechargeable battery and/or through the mains adapter (charger) with output voltage of 15 V (with charging from 220 V mains network)

    Dimensions, mm

    320×230×210

    Weight, kg

    4

    Operating temperature range

    from +1 °C to +40 °C

    Relative humidity, max.

    95±3 %

    Scope of delivery:

    No.

    Name

    Quantity

    1

    Radiometer RAMON-02AD

    1

    2

    +12 V power adapter

    1

    3

    PC connection cable

    1

    4

    How-to documentation (user manual, technical description and user guide)

    1

    5

    Warranty card

    1

    6

    Verification certificate

    1