SYSTEM OPERATING PRINCIPLES
The «ASKZ-01A» system is designed for:
«ASKZ-01A» consists of:
Number of detection units |
2 (for left and right hand) |
Detector type |
scintillation detector with ZnS(Ag) |
Area of the detection unit, cm2. |
300 |
Alpha radiation flux density measuring range, , particles/(cm2×min) |
0.05 to 5×105 |
Threshold alarm activation range, particles/(cm2×min) |
0.1 to 5×105 |
Threshold setting resolution, particles/(cm2×min) |
0.1 |
Fundamental measurement error, % |
±20 |
Operating temperature range, °С |
-40 to +50 |
Relative humidity, % |
Up to 95 |
Operating mode |
continuous (24/7) |
Configuration |
floor-standing, wall-mounted, desktop |
Overall dimensions, max., mm |
1290 × 930 × 600 |
Weight, max., kg |
25 |
Average service life, min., year |
10 |
The dosimeter is powered from a built-in 7.2V lithium-ion battery or from included adapter with 12V output voltage. |
DELIVERY KIT OF ASKZ-01A SYSTEM
№ |
Description |
Quantity |
1 |
Radiometer-dosimeter «RKS-01AS-SOLO», which includes: |
1 ea |
1.1 |
Dosimeter control panel with stand |
1 ea |
1.2 |
Alpha particle detection unit |
2 ea |
1.3 |
Rack |
3 ea |
1.4 |
Base |
1 ea |
1.5 |
Power adapter |
1 ea |
1.6 |
USB cable for connecting to a PC |
1 ea |
2 |
Access pass reader |
1 ea |
3 |
Turnstiles |
1 ea |
4 |
Video recording system |
1 ea |
5 |
Uninterruptible Power Supply |
1 ea |
6 |
Information display |
1 ea |
7 |
User manual (technical description and user guide) |
1 ea |
8 |
Data sheet |
1 ea |
The system also includes a personal computer, which transmits data from several automated systems of radiation exposure monitoring of hands “ASKZ-01A” for group “A” personnel.