Digital readout INFO-SOLO-01 is designed to display ambient equivalent dose rate measurements of gamma radiation received from the gamma radiation detection unit RKS-01GD-SOLO. An alarm is activated when threshold levels are exceeded: audible (with a different sound for each of the threshold levels) and visual (change of indicator color). Data is transferred to a computer via USB interface. Continuous 24/7 operation.
The RKS-01GD-SOLO detection unit is included in the State Register SI RK under no. KZ.02.01.02587-2024
Manufacturer: SOLO LLP
Country: Republic of Kazakhstan
Warranty period: 12 months
After-sales service: during the entire period of operation
The INFO-SOLO-01 digital readout is a stationary device designed to display gamma radiation equivalent dose rate measurements received from the RKS-01GD-SOLO gamma radiation detection unit, with a built-in clock and temperature sensor.
The INFO-SOLO-01 digital readout is supplied together with the RKS-01GD-SOLO gamma-radiation detection unit.
The INFO-SOLO-01 digital readout is supplied together with the RKS-01GD-SOLO gamma-radiation detection unit.
Characteristic |
Value |
|
Digital readout INFO-SOLO-01 |
||
ADER display range |
from 0.01 to 15×106 μSv/h |
|
Number of digits to display ADER readings |
three |
|
Margin of error of real-time clock |
±1 min in 48 hours |
|
Number of digits to display real time |
four |
|
Ambient temperature display range (one temperature sensor for temperature monitoring) |
from –40°С to +50°С |
|
Margin of error of temperature readings, max. |
±1°С in the range from –15°С to +50°С ±2°С in the range from –15°С to –40°С |
|
Number of digits to display temperature readings |
four |
|
Three preset threshold levels can be adjusted in a range |
from 0.01 μSv/h to 9.99 Sv/h with resolution of 0.01 μSv/h |
|
Threshold level alarm |
audible (with a different sound for each of the threshold levels), visual (change of color of ADER readings) |
|
Interface for network connection |
RS485 |
|
Power |
industrial 220 V mains source through a power adapter |
|
Readout operating mode |
24/7 |
|
Distance between the readout and the detection unit |
from 0.5 m to 50 m |
|
Installation |
vertical wall-mounted |
|
Gamma radiation detection unit RKS-01GD-SOLO |
||
Detector |
scintillation type |
|
Energy range of detected gamma X-ray radiation |
from 20 keV to 10 MeV |
|
Measurement range for ambient equivalent dose rate |
from 0.01 μSv/h to 15×106 Sv/h |
|
Maximum acceptable reference relative error |
±12% |
|
Rated voltage of the detection unit from an external power source: |
12 V |
|
Operating temperature range |
from –40°С to +50°С |
No. |
Name |
Quantity |
1 |
Digital readout INFO-SOLO-01 |
1 |
2 |
Detection unit RKS-01GD-SOLO |
1 |
3 |
Power supply with 5 V output voltage from 220 V mains source |
1 |
4 |
Control panel |
1 |
5 |
Connection cable of the detection unit |
1 |
6 |
Detection unit mounting kit |
1 |
7 |
RS-485/USB converter |
1 |
8 |
USB flash drive with software |
1 |
9 |
How-to documentation (user manual) |
1 |
10 |
Warranty card |
1 |
11 |
Verification certificate |
1 |