The RKS-01G-SOLO radiometer-dosimeter is designed for the detection of gamma radiation sources, operational radiation monitoring in areas and at enterprises requiring constant radiation monitoring.
The device has a handy LCD readout, as well as light sound alarm.
The device is included in the State Register of the Republic of Kazakhstan under no. KZ.02.01.02587-2024
Manufacturer: SOLO LLP
Country: Republic of Kazakhstan
Warranty period: 12 months
After-sales service: during the entire period of operation
The dosimeter is permanently installed in places of constant radiation monitoring and is designed to measure:
The dosimeter consists of a control panel and a built-in detection unit.
The flattening of nonlinearity of the energy dependence of the sensitivity of scintillators is performed by an analog-to-digital converter. The device performs basic radiation control tasks in accordance with the Hygiene Standards of the Sanitary and Epidemiological Guidelines for Radiation Safety (HS SEGRS) (NRB) and the of the Sanitary Rules of the Sanitary and Epidemiological Guidelines for Radiation Safety (SR SEGRS).
The device consists of a control panel and built-in detection unit.
Characteristic |
Value |
|
Gamma radiation detection unit |
||
Detector |
scintillation type |
|
Gamma radiation energy range |
from 20 keV to 10 MeV |
|
Measurement range for ambient equivalent dose rate |
from 0.01 to 500 μSv/h |
|
Measurement range for ambient equivalent dose |
from 0.01 to 5×108 μSv |
|
Maximum acceptable reference relative error |
±12% |
|
Wide-range gamma radiation detection unit |
||
Detector |
scintillation type |
|
Gamma radiation energy range |
from 20 keV to 10 MeV |
|
Measurement range for ambient equivalent dose rate |
from 0.01 to 15×106 μSv/h |
|
Measurement range for ambient equivalent dose |
from 0.01 to 5×108 μSv |
|
Maximum acceptable reference relative error |
±12% |
|
|
||
Overall dimensions of the control panel, max. |
170×100×90 mm |
|
Weight of the control panel, max. |
1.0 kg |
|
Operating temperature range of the control panel and detection units |
from –40°C to +50°C. |
|
For voice guidance and data storage |
from –40°C to +50°C. |
|
LCD data readout display |
from –30°C to +50°C. |
|
Power supply |
built-in 7.2 V lithium-ion battery or included AC adapter with 12 V output voltage |
No. |
Name |
Quantity |
1 |
Dosimeter control panel |
1 |
2 |
Power adapter |
1 |
3 |
PC connection cable |
1 |
4 |
CD (or flash drive) with software |
1 |
5 |
USB converter |
1 |
6 |
How-to documentation (user manual) |
1 |
7 |
Warranty card |
1 |
8 |
Verification certificate |
1 |