The RKS-01I-SOLO personal dosimeter is designed to measure the equivalent dose rate and cumulative dose of gamma radiation and beta-particle flux density for a given period. The dosimeter has a threshold-activated alarm warning.
The dosimeter is a compact and handy device for radiation and personal exposure monitoring.
The device is included in the State Register of the Republic of Kazakhstan under no. KZ.02.01.02587-2024
Manufacturer: SOLO LLP
Country: Republic of Kazakhstan
Warranty period: 12 months
After-sales service: during the entire period of operation
Video with a manual for working with the dosimeter: https://youtu.be/BbirhFlvmeQ
The dosimeter is a wearing device designed to measure:
The dosimeter consists of a control panel and built-in beta and gamma radiation detection units. Depending on the user’s needs, one or both of the detection units can be integrated (specifications are provided in the section “Main characteristics”).
The dosimeter fulfils the basic tasks of radiation monitoring in accordance with the requirements of the Hygienic Standards (HS SEGRS) (NRB), the Sanitary Guidelines (SG SEGRS) and other regulations.
The dosimeter consists of a control panel and built-in detection units.
Characteristic |
Value |
|
Beta-particle detector* |
||
Detector |
scintillation type |
|
Beta-particle flux density measuring range |
from 0.1 to 5×105 part/(min×cm2) |
|
Energy range of detected beta particles |
from 0.03 to 5 MeV |
|
Maximum acceptable reference relative error for beta radiation |
±15% |
|
Gamma radiation detection unit* |
||
Detector |
scintillation type |
|
Gamma radiation energy range |
from 20 keV to 10 MeV |
|
Measurement range for ambient equivalent dose rate |
from 0.01 to 500 μSv/h |
|
Measurement range for ambient equivalent dose |
from 0.01 to 5×108 μSv |
|
Maximum acceptable reference relative error |
±12% |
|
Wide-range gamma radiation detection unit* |
||
Detector |
scintillation type |
|
Gamma radiation energy range |
from 20 keV to 10 MeV |
|
Measurement range for ambient equivalent dose rate |
from 0.01 to 15×106 μSv/h |
|
Measurement range for ambient equivalent dose |
from 0.01 to 5×108 μSv |
|
Maximum acceptable reference relative error |
±12% |
|
Overall dimensions of the dosimeter, max. |
95×45×25 mm |
|
Dosimeter weight, max. |
0.09 kg |
|
Operating temperature range of the control panel and detection units |
from –40°C to +50°C. |
|
Power supply |
lithium-polymer battery |
|
* Depending on the user’s needs, one or both detection units described above can be installed |
No. |
Name |
Quantity |
1 |
Personal radiometer-dosimeter RKS-01I-SOLO |
1 |
2 |
Power adapter |
1 |
3 |
CD or flash drive with software |
1 |
4 |
USB cable |
1 |
5 |
Case |
1 |
6 |
How-to documentation (user manual) |
1 |
7 |
Warranty card |
1 |
8 |
Verification certificate |
1 |